Journal Description
Biosensors
Biosensors
is an international, peer-reviewed, open access journal on the technology and science of biosensors published monthly online by MDPI.
- Open Access— free for readers, with article processing charges (APC) paid by authors or their institutions.
- High Visibility: indexed within Scopus, SCIE (Web of Science), PubMed, MEDLINE, PMC, Embase, CAPlus / SciFinder, Inspec, and other databases.
- Journal Rank: JCR - Q1 (Chemistry, Analytical) / CiteScore - Q1 (Engineering (miscellaneous))
- Rapid Publication: manuscripts are peer-reviewed and a first decision is provided to authors approximately 17.7 days after submission; acceptance to publication is undertaken in 2.6 days (median values for papers published in this journal in the first half of 2023).
- Recognition of Reviewers: reviewers who provide timely, thorough peer-review reports receive vouchers entitling them to a discount on the APC of their next publication in any MDPI journal, in appreciation of the work done.
Impact Factor:
5.4 (2022);
5-Year Impact Factor:
5.7 (2022)
Latest Articles
Label-Free DNA Biosensor Based on Reduced Graphene Oxide and Gold Nanoparticles
Biosensors 2023, 13(8), 797; https://doi.org/10.3390/bios13080797 - 08 Aug 2023
Abstract
Currently available DNA detection techniques frequently require compromises between simplicity, speed, accuracy, and cost. Here, we propose a simple, label-free, and cost-effective DNA detection platform developed at screen-printed carbon electrodes (SPCEs) modified with reduced graphene oxide (RGO) and gold nanoparticles (AuNPs). The preparation
[...] Read more.
Currently available DNA detection techniques frequently require compromises between simplicity, speed, accuracy, and cost. Here, we propose a simple, label-free, and cost-effective DNA detection platform developed at screen-printed carbon electrodes (SPCEs) modified with reduced graphene oxide (RGO) and gold nanoparticles (AuNPs). The preparation of the detection platform involved a two-step electrochemical procedure based on GO reduction onto SPCEs followed by the electrochemical reduction of HAuCl4 to facilitate the post-grafting reaction with AuNPs. The final sensor was fabricated by the simple physical adsorption of a single-stranded DNA (ssDNA) probe onto a AuNPs–RGO/SPCE electrode. Each preparation step was confirmed by morphological and structural characterization using scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy, respectively. Furthermore, the electrochemical properties of the modified electrodes have been investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The results demonstrated that the introduction of AuNPs onto RGO/SPCEs led to an enhancement in surface conductivity, a characteristic that favored an increased sensitivity in detection. The detection process relied on the change in the electrochemical signal induced by the binding of target DNA to the bioreceptor and was particularly monitored by the change in the charge transfer resistance of a [Fe(CN)6]4–/3– redox couple added in the test solution.
Full article
(This article belongs to the Special Issue Application of Graphene-Based Sensors in Biomolecular Detection)
Open AccessReview
Early-Stage Detection of Biotic and Abiotic Stress on Plants by Chlorophyll Fluorescence Imaging Analysis
Biosensors 2023, 13(8), 796; https://doi.org/10.3390/bios13080796 - 08 Aug 2023
Abstract
Most agricultural land, as a result of climate change, experiences severe stress that significantly reduces agricultural yields. Crop sensing by imaging techniques allows early-stage detection of biotic or abiotic stress to avoid damage and significant yield losses. Among the top certified imaging techniques
[...] Read more.
Most agricultural land, as a result of climate change, experiences severe stress that significantly reduces agricultural yields. Crop sensing by imaging techniques allows early-stage detection of biotic or abiotic stress to avoid damage and significant yield losses. Among the top certified imaging techniques for plant stress detection is chlorophyll a fluorescence imaging, which can evaluate spatiotemporal leaf changes, permitting the pre-symptomatic monitoring of plant physiological status long before any visible symptoms develop, allowing for high-throughput assessment. Here, we review different examples of how chlorophyll a fluorescence imaging analysis can be used to evaluate biotic and abiotic stress. Chlorophyll a is able to detect biotic stress as early as 15 min after Spodoptera exigua feeding, or 30 min after Botrytis cinerea application on tomato plants, or on the onset of water-deficit stress, and thus has potential for early stress detection. Chlorophyll fluorescence (ChlF) analysis is a rapid, non-invasive, easy to perform, low-cost, and highly sensitive method that can estimate photosynthetic performance and detect the influence of diverse stresses on plants. In terms of ChlF parameters, the fraction of open photosystem II (PSII) reaction centers (qp) can be used for early stress detection, since it has been found in many recent studies to be the most accurate and appropriate indicator for ChlF-based screening of the impact of environmental stress on plants.
Full article
(This article belongs to the Special Issue Fluorescence and Spectroscopic Techniques in Agriculture and Biological Products)
►▼
Show Figures
Figure 1
Open AccessPerspective
Liquid Metal-Based Flexible Bioelectrodes for Management of In-Stent-Restenosis: Potential Application
Biosensors 2023, 13(8), 795; https://doi.org/10.3390/bios13080795 - 07 Aug 2023
Abstract
Although vascular stents have been widely used in clinical practice, there is still a risk of in-stent restenosis after their implantation. Combining conventional vascular stents with liquid metal-based electrodes with impedance detection, irreversible electroporation, and blood pressure detection provides a new direction to
[...] Read more.
Although vascular stents have been widely used in clinical practice, there is still a risk of in-stent restenosis after their implantation. Combining conventional vascular stents with liquid metal-based electrodes with impedance detection, irreversible electroporation, and blood pressure detection provides a new direction to completely solve the restenosis problem. Compared with conventional rigid electrodes, liquid metal-based electrodes combine high conductivity and stretchability, and are more compliant with the implantation process of vascular stents and remain in the vasculature for a long period of time. This perspective reviews the types and development of conventional vascular stents and proposes a novel stent that integrates liquid metal-based electrodes on conventional vascular stents. This vascular stent has three major functions of prediction, detection and treatment, and is expected to be a new generation of cardiovascular implant with intelligent sensing and real-time monitoring.
Full article
(This article belongs to the Special Issue Liquid Metal Based Biosensors and Bioelectronic Devices)
►▼
Show Figures
Figure 1
Open AccessArticle
Characterization of Benchtop-Fabricated Arrays of Nanowrinkled Surface Electrodes as a Nitric Oxide Electrochemical Sensor
Biosensors 2023, 13(8), 794; https://doi.org/10.3390/bios13080794 - 07 Aug 2023
Abstract
In this work, we present an accessible benchtop fabrication technique to obtain a planar array of gold nanowrinkled surface electrodes (ANSE) for the construction of electrochemical cells, specifically to monitor soluble biomarkers of interest in cell culture environments. We present a complete characterization
[...] Read more.
In this work, we present an accessible benchtop fabrication technique to obtain a planar array of gold nanowrinkled surface electrodes (ANSE) for the construction of electrochemical cells, specifically to monitor soluble biomarkers of interest in cell culture environments. We present a complete characterization of the array and its response as an electrochemical cell. To validate our sensor, we evaluated the device sensitivity to detect nitric oxide (NO), an important molecule produced by endothelial cells as a response to environmental signals such as mechanics and growth factors. While testing measurements of nitric oxide in aqueous solutions with isotonic salt concentrations, we evidenced the influence of the environmental conditions for such electrochemical measurements, showing that the aqueous medium, usually not accounted for, significantly impacts the outcome. Finally, we present the application of the electrochemical sensor for the detection of nitric oxide released from stimulated endothelial cells as a proof of concept.
Full article
(This article belongs to the Special Issue Construction of Biosensors Using Nano- and Microtechnology)
►▼
Show Figures
Figure 1
Open AccessArticle
Effect of Hydrogen Plasma Treatment on the Sensitivity of ZnO Based Electrochemical Non-Enzymatic Biosensor
by
, , , , and
Biosensors 2023, 13(8), 793; https://doi.org/10.3390/bios13080793 - 07 Aug 2023
Abstract
Information on vitamin C—ascorbic acid (AA)—content is important as it facilitates the provision of dietary advice and strategies for the prevention and treatment of conditions associated with AA deficiency or excess. The methods of determining AA content include chromatographic techniques, spectrophotometry, and electrochemical
[...] Read more.
Information on vitamin C—ascorbic acid (AA)—content is important as it facilitates the provision of dietary advice and strategies for the prevention and treatment of conditions associated with AA deficiency or excess. The methods of determining AA content include chromatographic techniques, spectrophotometry, and electrochemical methods of analysis. In the present work, an electrochemical enzyme-free ascorbic acid sensor for a neutral medium has been developed. The sensor is based on zinc oxide nanowire (ZnO NW) arrays synthesized via low-temperature chemical deposition (Chemical Bath Deposition) on the surface of an ITO substrate. The sensitivity of the electrochemical enzyme-free sensor was found to be dependent on the process treatments. The AA sensitivity values measured in a neutral PBS electrolyte were found to be 73, 44, and 92 µA mM−1 cm−2 for the ZnO NW-based sensors of the pristine, air-annealed (AT), and air-annealed followed by hydrogen plasma treatment (AT+PT), respectively. The simple H-plasma treatment of ZnO nanowire arrays synthesized via low-temperature chemical deposition has been shown to be an effective process step to produce an enzyme-free sensor for biological molecules in a neutral electrolyte for applications in health care and biomedical safety.
Full article
(This article belongs to the Topic Advanced Nanomaterials for Sensing Applications)
►▼
Show Figures
Figure 1
Open AccessArticle
Fast-Response Non-Contact Flexible Humidity Sensor Based on Direct-Writing Printing for Respiration Monitoring
Biosensors 2023, 13(8), 792; https://doi.org/10.3390/bios13080792 - 07 Aug 2023
Abstract
Respiratory monitoring is crucial for evaluating health status and identifying potential respiratory diseases such as respiratory failure, bronchitis, and pneumonia. Humidity sensors play a significant role in this regard, and efforts are being made to improve their performance. However, achieving ideal sensor parameters
[...] Read more.
Respiratory monitoring is crucial for evaluating health status and identifying potential respiratory diseases such as respiratory failure, bronchitis, and pneumonia. Humidity sensors play a significant role in this regard, and efforts are being made to improve their performance. However, achieving ideal sensor parameters such as sensitivity, detection range, and response speed is challenging. In this work, we propose a flexible preparation method for a double-layer humidity sensor using PDMS as a substrate and a GNP/MWCNT composite material as a sensor element. This sensor exhibits high sensitivity (1.4 RH-1), a wide detection range (20–90%), ultra-fast response (0.35 s) and recovery (2.5 s), high repetitiveness (500 cycles), good long-term stability, and excellent flexibility. Due to these advantages, this sensor has potential applications in real-time clinical and home medical care, such as accurate human respiratory monitoring and non-invasive skin humidity monitoring. Hence, this humidity sensor can be a powerful tool to monitor respiratory moisture levels for diagnosing and treating respiratory diseases effectively.
Full article
(This article belongs to the Section Nano- and Micro-Technologies in Biosensors)
►▼
Show Figures
Figure 1
Open AccessArticle
Development and Evaluation of a Flexible PVDF-Based Balloon Sensor for Detecting Mechanical Forces at Key Esophageal Nodes in Esophageal Motility Disorders
by
, , , , , , and
Biosensors 2023, 13(8), 791; https://doi.org/10.3390/bios13080791 - 04 Aug 2023
Abstract
Prevailing methods for esophageal motility assessments, such as perfusion manometry and probe-based function imaging, frequently overlook the intricate stress fields acting on the liquid-filled balloons at the forefront of the probing device within the esophageal lumen. To bridge this knowledge gap, we innovatively
[...] Read more.
Prevailing methods for esophageal motility assessments, such as perfusion manometry and probe-based function imaging, frequently overlook the intricate stress fields acting on the liquid-filled balloons at the forefront of the probing device within the esophageal lumen. To bridge this knowledge gap, we innovatively devised an infusible flexible balloon catheter, equipped with a quartet of PVDF piezoelectric sensors. This design, working in concert with a bespoke local key-node analytical algorithm and a sensor array state analysis model, seeks to shed new light on the dynamic mechanical characteristics at pivotal esophageal locales. To further this endeavor, we pioneered a singular closed balloon system and a complementary signal acquisition and processing system that employs a homogeneously distributed PVDF piezoelectric sensor array for the real-time monitoring of dynamic mechanical nuances in the esophageal segment. An advanced analytical model was established to scrutinize the coupled physical fields under varying degrees of balloon inflation, thereby facilitating a thorough dynamic stress examination of local esophageal nodes. Our rigorous execution of static, dynamic, and simulated swallowing experiments robustly substantiated the viability of our design, the logical coherence of our esophageal key-point stress analytical algorithm, and the potential clinical utility of a flexible esophageal key-node stress detection balloon probe outfitted with a PVDF array. This study offers a fresh lens through which esophageal motility testing can be viewed and improved upon.
Full article
(This article belongs to the Special Issue Emerging Point-of-Care Biosensors and Their Applications)
►▼
Show Figures
Figure 1
Open AccessArticle
An Integrated Microfluidic Biosensing System Based on a Versatile Valve and Recombinase Polymerase Amplification for Rapid and Sensitive Detection of Salmonella typhimurium
Biosensors 2023, 13(8), 790; https://doi.org/10.3390/bios13080790 - 04 Aug 2023
Abstract
Detecting foodborne pathogens on-site is crucial for ensuring food safety, necessitating the development of rapid, cost-effective, highly sensitive, and portable devices. This paper presents an integrated microfluidic biosensing system designed for the rapid and sensitive detection of Salmonella typhimurium (S. typhimurium). The
[...] Read more.
Detecting foodborne pathogens on-site is crucial for ensuring food safety, necessitating the development of rapid, cost-effective, highly sensitive, and portable devices. This paper presents an integrated microfluidic biosensing system designed for the rapid and sensitive detection of Salmonella typhimurium (S. typhimurium). The biosensing system comprises a microfluidic chip with a versatile valve, a recombinase polymerase amplification (RPA) for nucleic acid detection, and a customized real-time fluorescence detection system. The versatile valve combines the functions of an active valve and a magnetic actuation mixer, enabling on-demand mixing and controlling fluid flow. Quantitative fluorescence is processed and detected through a custom-built smartphone application. The proposed integrated microfluidic biosensing system could detect Salmonella at concentrations as low as 1.0 × 102 copies/µL within 30 min, which was consistent with the results obtained from the real-time quantitative polymerase chain reaction (qPCR) tests. With its versatile valve, this integrated microfluidic biosensing system holds significant potential for on-site detection of foodborne pathogens.
Full article
(This article belongs to the Special Issue Biosensors for Agriculture, Environment and Food)
►▼
Show Figures
Figure 1
Open AccessArticle
Label-Free Analysis of Urine Samples with In-Flow Digital Holographic Microscopy
by
, , , and
Biosensors 2023, 13(8), 789; https://doi.org/10.3390/bios13080789 - 04 Aug 2023
Abstract
Urinary tract infections are among the most frequent infectious diseases and require screening a great amount of urine samples from patients. However, a high percentage of samples result as negative after urine culture plate tests (CPTs), demanding a simple and fast preliminary technique
[...] Read more.
Urinary tract infections are among the most frequent infectious diseases and require screening a great amount of urine samples from patients. However, a high percentage of samples result as negative after urine culture plate tests (CPTs), demanding a simple and fast preliminary technique to screen out the negative samples. We propose a digital holographic microscopy (DHM) method to inspect fresh urine samples flowing in a glass capillary for 3 min, recording holograms at 2 frames per second. After digital reconstruction, bacteria, white and red blood cells, epithelial cells and crystals were identified and counted, and the samples were classified as negative or positive according to clinical cutoff values. Taking the CPT as reference, we processed 180 urine samples and compared the results with those of urine flow cytometry (UFC). Using standard evaluation metrics for our screening test, we found a similar performance for DHM and UFC, indicating DHM as a suitable and fast screening technique retaining several advantages. As a benefit of DHM, the technique is label-free and does not require sample preparation. Moreover, the phase and amplitude images of the cells and other particles present in urine are digitally recorded and can serve for further investigation afterwards.
Full article
(This article belongs to the Special Issue Advanced Optical Sensing Techniques for Applications in Biomedicine)
►▼
Show Figures
Figure 1
Open AccessArticle
A Polarity-Sensitive Far-Red Fluorescent Probe for Glucose Sensing through Skin
Biosensors 2023, 13(8), 788; https://doi.org/10.3390/bios13080788 - 04 Aug 2023
Abstract
The field of glucose biosensors for diabetes management has been of great interest over the past 60 years. Continuous glucose monitoring (CGM) is important to continuously track the glucose level to provide better management of the disease. Concanavalin A (ConA) can reversibly bind
[...] Read more.
The field of glucose biosensors for diabetes management has been of great interest over the past 60 years. Continuous glucose monitoring (CGM) is important to continuously track the glucose level to provide better management of the disease. Concanavalin A (ConA) can reversibly bind to glucose and mannose molecules and form a glucose biosensor via competitive binding. Here, we developed a glucose biosensor using ConA and a fluorescent probe, which generated a fluorescent intensity change based on solvatochromism, the reversible change in the emission spectrum dependent on the polarity of the solvent. The direction in which the wavelength shifts as the solvent polarity increases can be defined as positive (red-shift), negative (blue-shift), or a combination of the two, referred to as reverse. To translate this biosensor to a subcutaneously implanted format, Cyanine 5.5 (Cy5.5)-labeled small mannose molecules were used, which allows for the far-red excitation wavelength range to increase the skin penetration depth of the light source and returned emission. Three Cy5.5-labeled small mannose molecules were synthesized and compared when used as the competing ligand in the competitive binding biosensor. We explored the polarity-sensitive nature of the competing ligands and examined the biosensor’s glucose response. Cy5.5-mannotetraose performed best as a biosensor, allowing for the detection of glucose from 25 to 400 mg/dL. Thus, this assay is responsive to glucose within the physiologic range when its concentration is increased to levels needed for an implantable design. The biosensor response is not statistically different when placed under different skin pigmentations when comparing the percent increase in fluorescence intensity. This shows the ability of the biosensor to produce a repeatable signal across the physiologic range for subcutaneous glucose monitoring under various skin tones.
Full article
(This article belongs to the Special Issue Advances in Optical Biosensors and Chemical Sensors)
►▼
Show Figures
Figure 1
Open AccessReview
Electric Double Layer Based Epidermal Electronics for Healthcare and Human-Machine Interface
Biosensors 2023, 13(8), 787; https://doi.org/10.3390/bios13080787 - 03 Aug 2023
Abstract
Epidermal electronics, an emerging interdisciplinary field, is advancing the development of flexible devices that can seamlessly integrate with the skin. These devices, especially Electric Double Layer (EDL)-based sensors, overcome the limitations of conventional electronic devices, offering high sensitivity, rapid response, and excellent stability.
[...] Read more.
Epidermal electronics, an emerging interdisciplinary field, is advancing the development of flexible devices that can seamlessly integrate with the skin. These devices, especially Electric Double Layer (EDL)-based sensors, overcome the limitations of conventional electronic devices, offering high sensitivity, rapid response, and excellent stability. Especially, Electric Double Layer (EDL)-based epidermal sensors show great potential in the application of wearable electronics to detect biological signals due to their high sensitivity, fast response, and excellent stability. The advantages can be attributed to the biocompatibility of the materials, the flexibility of the devices, and the large capacitance due to the EDL effect. Furthermore, we discuss the potential of EDL epidermal electronics as wearable sensors for health monitoring and wound healing. These devices can analyze various biofluids, offering real-time feedback on parameters like pH, temperature, glucose, lactate, and oxygen levels, which aids in accurate diagnosis and effective treatment. Beyond healthcare, we explore the role of EDL epidermal electronics in human-machine interaction, particularly their application in prosthetics and pressure-sensing robots. By mimicking the flexibility and sensitivity of human skin, these devices enhance the functionality and user experience of these systems. This review summarizes the latest advancements in EDL-based epidermal electronic devices, offering a perspective for future research in this rapidly evolving field.
Full article
(This article belongs to the Special Issue Epidermal Electronics and Implantable Devices)
►▼
Show Figures
Figure 1
Open AccessReview
Recent Advances in Quantum Dot-Based Lateral Flow Immunoassays for the Rapid, Point-of-Care Diagnosis of COVID-19
by
, , , , and
Biosensors 2023, 13(8), 786; https://doi.org/10.3390/bios13080786 - 03 Aug 2023
Abstract
The COVID-19 pandemic has spurred demand for efficient and rapid diagnostic tools that can be deployed at point of care to quickly identify infected individuals. Existing detection methods are time consuming and they lack sensitivity. Point-of-care testing (POCT) has emerged as a promising
[...] Read more.
The COVID-19 pandemic has spurred demand for efficient and rapid diagnostic tools that can be deployed at point of care to quickly identify infected individuals. Existing detection methods are time consuming and they lack sensitivity. Point-of-care testing (POCT) has emerged as a promising alternative due to its user-friendliness, rapidity, and high specificity and sensitivity. Such tests can be conveniently conducted at the patient’s bedside. Immunodiagnostic methods that offer the rapid identification of positive cases are urgently required. Quantum dots (QDs), known for their multimodal properties, have shown potential in terms of combating or inhibiting the COVID-19 virus. When coupled with specific antibodies, QDs enable the highly sensitive detection of viral antigens in patient samples. Conventional lateral flow immunoassays (LFAs) have been widely used for diagnostic testing due to their simplicity, low cost, and portability. However, they often lack the sensitivity required to accurately detect low viral loads. Quantum dot (QD)-based lateral flow immunoassays have emerged as a promising alternative, offering significant advancements in sensitivity and specificity. Moreover, the lateral flow immunoassay (LFIA) method, which fulfils POCT standards, has gained popularity in diagnosing COVID-19. This review focuses on recent advancements in QD-based LFIA for rapid POCT COVID-19 diagnosis. Strategies to enhance sensitivity using QDs are explored, and the underlying principles of LFIA are elucidated. The benefits of using the QD-based LFIA as a POCT method are highlighted, and its published performance in COVID-19 diagnostics is examined. Overall, the integration of quantum dots with LFIA holds immense promise in terms of revolutionizing COVID-19 detection, treatment, and prevention, offering a convenient and effective approach to combat the pandemic.
Full article
(This article belongs to the Special Issue COVID-19 Biosensing Technology)
►▼
Show Figures
Figure 1
Open AccessReview
Biosensors with Boronic Acid-Based Materials as the Recognition Elements and Signal Labels
Biosensors 2023, 13(8), 785; https://doi.org/10.3390/bios13080785 - 03 Aug 2023
Abstract
It is of great importance to have sensitive and accurate detection of cis-diol-containing biologically related substances because of their important functions in the research fields of metabolomics, glycomics, and proteomics. Boronic acids can specifically and reversibly interact with 1,2- or 1,3-diols to
[...] Read more.
It is of great importance to have sensitive and accurate detection of cis-diol-containing biologically related substances because of their important functions in the research fields of metabolomics, glycomics, and proteomics. Boronic acids can specifically and reversibly interact with 1,2- or 1,3-diols to form five or six cyclic esters. Based on this unique property, boronic acid-based materials have been used as synthetic receptors for the specific recognition and detection of cis-diol-containing species. This review critically summarizes the recent advances with boronic acid-based materials as recognition elements and signal labels for the detection of cis-diol-containing biological species, including ribonucleic acids, glycans, glycoproteins, bacteria, exosomes, and tumor cells. We also address the challenges and future perspectives for developing versatile boronic acid-based materials with various promising applications.
Full article
(This article belongs to the Special Issue Biosensors Based on Self-Assembly and Boronate Affinity Interaction)
►▼
Show Figures
Figure 1
Open AccessArticle
Study of SARS-CoV-2 Spike Protein Wild-Type and the Variants of Concern Real-Time Interactions with Monoclonal Antibodies and Convalescent Human Serum
by
, , , and
Biosensors 2023, 13(8), 784; https://doi.org/10.3390/bios13080784 - 03 Aug 2023
Abstract
The spike (S) protein and its receptor-binding domain (RBD) of the coronavirus SARS-CoV-2 have been continually evolving, yielding the majority of significant missense mutations and new variants of concern. In this study, we examined how monoclonal antibodies against RBD (mAbs-SCoV2-RBD) and polyclonal antibodies
[...] Read more.
The spike (S) protein and its receptor-binding domain (RBD) of the coronavirus SARS-CoV-2 have been continually evolving, yielding the majority of significant missense mutations and new variants of concern. In this study, we examined how monoclonal antibodies against RBD (mAbs-SCoV2-RBD) and polyclonal antibodies present in convalescent human serum specifically interact with the S protein of wild-type and SARS-CoV-2 variants of concern (VOCs) in real time and how this can be reflected through surface mass density. Moreover, we combined two distinct, label-free measurement techniques: one based on changes in surface electromagnetic waves after reflection from the surface, and the other on changes in acoustic waves. The results demonstrated that dry surface mass density (ΓSE) of mAbs-SCoV2-RBD attached to the RBD of the S protein decreases three-fold, from 148 ng/cm2 to 46 ng/cm2, due to the B.1.351 or so-called beta mutation of coronavirus and its S protein (SCoV2-β). Consequently, the obtained wet mass ΓQCM-D resulted in values two times lower, from 319 ng/cm2 to 158 ng/cm2, and the hydration of mAbs-SCoV2-RBD/SCoV2-β immune complex was 70.88%. Conversely, when polyclonal antibodies present in convalescent human serum form immune complexes with the S protein of SARS-CoV-2 variants of concern, the ΓSE decreased from 279 ng/cm2 to 249 ng/cm2, and ΓQCM-D from 1545 ng/cm2 to 1366 ng/cm2. These results can give insights into the differences between the interaction of monoclonal and polyclonal antibodies with SARS-CoV-2 VOCs.
Full article
(This article belongs to the Section Optical and Photonic Biosensors)
►▼
Show Figures
Graphical abstract
Open AccessArticle
Methylene-Blue-Encapsulated Metal-Organic-Framework-Based Electrochemical POCT Platform for Multiple Detection of Heavy Metal Ions in Milk
Biosensors 2023, 13(8), 783; https://doi.org/10.3390/bios13080783 - 02 Aug 2023
Abstract
Considering the high risk of heavy metal ions (HMIs) transferring through the food chain and accumulating in milk, a flexible and facile point-of-care testing (POCT) platform is urgently needed for the accurate, sensitive, and highly selective on-site quantification of multiple HMIs in milk.
[...] Read more.
Considering the high risk of heavy metal ions (HMIs) transferring through the food chain and accumulating in milk, a flexible and facile point-of-care testing (POCT) platform is urgently needed for the accurate, sensitive, and highly selective on-site quantification of multiple HMIs in milk. In this work, a cost-effective disk with six screen-printed electrodes (SPEs) was designed for hand-held electrochemical detection. Metal organic frameworks (MOFs) were adopted to amplify and enhance the electrochemical signals of methylene blue (MB). Using differential pulse voltammetry (DPV) methods, low limits of detection for four HMIs (Cd2+, 0.039 ppb; Hg2+, 0.039 ppb; Pb2+, 0.073 ppb; and As3+, 0.022 ppb) were achieved within four minutes. Moreover, the quantitative POCT system was applied to milk samples. The advantages of low cost, ease of on-site implementation, fast response, and accuracy allow for the POCT platform to be used in practical monitoring applications for the quantitation of multiple HMIs in milk samples.
Full article
(This article belongs to the Special Issue Electrochemiluminescence Biosensors for Imaging or Detection of Biomarkers, Virus, Bacteria, and Metal Ions)
►▼
Show Figures
Figure 1
Open AccessArticle
Highly Sensitive and Specific Detection of Influenza A Viruses Using Bimolecular Fluorescence Complementation (BiFC) Reporter System
Biosensors 2023, 13(8), 782; https://doi.org/10.3390/bios13080782 - 02 Aug 2023
Abstract
In this study, we developed a highly sensitive and specific bimolecular fluorescence complementation (BiFC)-based influenza A virus (IAV)-sensing system by combining a galactose/glucose-binding protein (GGBP) with an N-terminal large domain (YN1-172) and a C-terminal small domain (YC173-239) made up of enhanced yellow fluorescence
[...] Read more.
In this study, we developed a highly sensitive and specific bimolecular fluorescence complementation (BiFC)-based influenza A virus (IAV)-sensing system by combining a galactose/glucose-binding protein (GGBP) with an N-terminal large domain (YN1-172) and a C-terminal small domain (YC173-239) made up of enhanced yellow fluorescence protein (eYFP). The GGBP-based BiFC reporter exhibits the fluorescence reconstitution as a result of conformational changes in GGBP when lactose, which was derived from 6′-silalyllactose and used as a substrate for neuraminidase (NA), binds to GGBP in the presence of IAV. The system showed a linear dynamic range extending from 1 × 100 to 1 × 107 TCID50/mL, and it had a detection limit of 1.1 × 100 TCID50/mL for IAV (H1N1), demonstrating ultra-high sensitivity. Our system exhibited fluorescence intensity enhancements in the presence of IAV, while it displayed weak fluorescence signals when exposed to NA-deficient viruses, such as RSV A, RSV B, adenovirus and rhinovirus, thereby indicating selective responses for IAV detection. Overall, our system provides a simple, highly sensitive and specific IAV detection platform based on BiFC that is capable of detecting ligand-induced protein conformational changes, obviating the need for virus culture or RNA extraction processes.
Full article
(This article belongs to the Special Issue Bio-Nanotechnology for Bio-Sensing, Imaging, and Cancer Therapy)
►▼
Show Figures
Figure 1
Open AccessArticle
Electrochemical Sensing Platform Based on Metal Nanoparticles for Epinephrine and Serotonin
Biosensors 2023, 13(8), 781; https://doi.org/10.3390/bios13080781 - 01 Aug 2023
Abstract
A sensing platform based on nanocomposite materials composed of gold metal nanoparticles (AuNPs) and conducting polymer (CP) matrix has been developed for serotonin and epinephrine detection. The CP-AuNPs nanocomposite materials have been synthesized onto glassy carbon electrodes (GCE) by using novel electrochemical procedures
[...] Read more.
A sensing platform based on nanocomposite materials composed of gold metal nanoparticles (AuNPs) and conducting polymer (CP) matrix has been developed for serotonin and epinephrine detection. The CP-AuNPs nanocomposite materials have been synthesized onto glassy carbon electrodes (GCE) by using novel electrochemical procedures based on sinusoidal currents (SC). The SC procedures ensured good control of the metal nanoparticles distribution, increased electrochemical surface area, and enhanced analytical performance. The proposed sensing platform displayed good analytical performance toward serotonin and epinephrine detection. A wide linear analytical response toward epinephrine in the range from 10 to 640 μM and a low detection limit of 1.4 μM epinephrine has been obtained. The sensing platform has also displayed a linear response toward serotonin in the range from 10 to 320 μM, with a detection limit of 5.7 μM serotonin. The sensing platform has been successfully applied in the analysis of epinephrine and serotonin in real samples of tap water and urine with good accuracy.
Full article
(This article belongs to the Special Issue Electrochemical Sensors and Biosensors for Environmental, Health, and Food Safety Applications)
►▼
Show Figures
Figure 1
Open AccessArticle
Green-Mediated Synthesis of NiCo2O4 Nanostructures Using Radish White Peel Extract for the Sensitive and Selective Enzyme-Free Detection of Uric Acid
by
, , , , , , , , , , , and
Biosensors 2023, 13(8), 780; https://doi.org/10.3390/bios13080780 - 01 Aug 2023
Abstract
The ability to measure uric acid (UA) non-enzymatically in human blood has been demonstrated through the use of a simple and efficient electrochemical method. A phytochemical extract from radish white peel extract improved the electrocatalytic performance of nickel–cobalt bimetallic oxide (NiCo2O
[...] Read more.
The ability to measure uric acid (UA) non-enzymatically in human blood has been demonstrated through the use of a simple and efficient electrochemical method. A phytochemical extract from radish white peel extract improved the electrocatalytic performance of nickel–cobalt bimetallic oxide (NiCo2O4) during a hydrothermal process through abundant surface holes of oxides, an alteration of morphology, an excellent crystal quality, and increased Co(III) and Ni(II) chemical states. The surface structure, morphology, crystalline quality, and chemical composition were determined using a variety of analytical techniques, including powder X-ray diffraction (XRD), scanning electron microscopy (SEM), high-resolution transmission electron microscopy (HR-TEM), and X-ray photoelectron spectroscopy (XPS). The electrochemical characterization by CV revealed a linear range of UA from 0.1 mM to 8 mM, with a detection limit of 0.005 mM and a limit of quantification (LOQ) of 0.008 mM. A study of the sensitivity of NiCo2O4 nanostructures modified on the surface to UA detection with amperometry has revealed a linear range from 0.1 mM to 4 mM for detection. High stability, repeatability, and selectivity were associated with the enhanced electrochemical performance of non-enzymatic UA sensing. A significant contribution to the full outperforming sensing characterization can be attributed to the tailoring of surface properties of NiCo2O4 nanostructures. EIS analysis revealed a low charge-transfer resistance of 114,970 Ohms that offered NiCo2O4 nanostructures prepared with 5 mL of radish white peel extract, confirming an enhanced performance of the presented non-enzymatic UA sensor. As well as testing the practicality of the UA sensor, blood samples from human beings were also tested for UA. Due to its high sensitivity, stability, selectivity, repeatability, and simplicity, the developed non-enzymatic UA sensor is ideal for monitoring UA for a wide range of concentrations in biological matrixes.
Full article
(This article belongs to the Special Issue Recent Advances in Nano-Biomaterial-Based Biosensors)
►▼
Show Figures
Figure 1
Open AccessArticle
Fluoropolymer Functionalization of Organ-on-Chip Platform Increases Detection Sensitivity for Cannabinoids
by
, , , , , , , , , and
Biosensors 2023, 13(8), 779; https://doi.org/10.3390/bios13080779 - 01 Aug 2023
Abstract
Microfluidic technology is applied across various research areas including organ-on-chip (OOC) systems. The main material used for microfluidics is polydimethylsiloxane (PDMS), a silicone elastomer material that is biocompatible, transparent, and easy to use for OOC systems with well-defined microstructures. However, PDMS-based OOC systems
[...] Read more.
Microfluidic technology is applied across various research areas including organ-on-chip (OOC) systems. The main material used for microfluidics is polydimethylsiloxane (PDMS), a silicone elastomer material that is biocompatible, transparent, and easy to use for OOC systems with well-defined microstructures. However, PDMS-based OOC systems can absorb hydrophobic and small molecules, making it difficult and erroneous to make quantitative analytical assessments for such compounds. In this paper, we explore the use of a synthetic fluoropolymer, poly(4,5-difluoro-2,2-bis(trifluoromethyl)-1,3-dioxole-co-tetrafluoroethylene) (Teflon™ AF 2400), with excellent “non-stick” properties to functionalize OOC systems. Cannabinoids, including cannabidiol (CBD), are classes of hydrophobic compounds with a great potential for the treatment of anxiety, depression, pain, and cancer. By using CBD as a testing compound, we examined and systematically quantified CBD absorption into PDMS by means of an LC-MS/MS analysis. In comparison to the unmodified PDMS microchannels, an increase of approximately 30× in the CBD signal was detected with the fluoropolymer surface modification after 3 h of static incubation. Under perfusion conditions, we observed an increase of nearly 15× in the CBD signals from the surface-modified microchannels than from the unmodified microchannels. Furthermore, we also demonstrated that fluoropolymer-modified microchannels are compatible for culturing hCMEC/D3 endothelial cells and for CBD perfusion experiments.
Full article
(This article belongs to the Special Issue Fluorescent Probe and Organ-on-Chip for Drug Delivery and Development)
►▼
Show Figures
Figure 1
Open AccessArticle
A Chamber-Based Digital PCR Based on a Microfluidic Chip for the Absolute Quantification and Analysis of KRAS Mutation
by
, , , , , , , , , and
Biosensors 2023, 13(8), 778; https://doi.org/10.3390/bios13080778 - 01 Aug 2023
Abstract
The Kirsten rat sarcoma virus gene (KRAS) is the most common tumor in human cancer, and KRAS plays an important role in the growth of tumor cells. Normal KRAS inhibits tumor cell growth. When mutated, it will continuously stimulate cell growth, resulting in
[...] Read more.
The Kirsten rat sarcoma virus gene (KRAS) is the most common tumor in human cancer, and KRAS plays an important role in the growth of tumor cells. Normal KRAS inhibits tumor cell growth. When mutated, it will continuously stimulate cell growth, resulting in tumor development. There are currently few drugs that target the KRAS gene. Here, we developed a microfluidic chip. The chip design uses parallel fluid channels combined with cylindrical chamber arrays to generate 20,000 cylindrical microchambers. The microfluidic chip designed by us can be used for the microsegmentation of KRAS gene samples. The thermal cycling required for the PCR stage is performed on a flat-panel instrument and detected using a four-color fluorescence system. “Glass-PDMS-glass” sandwich structure effectively reduces reagent volatilization; in addition, a valve is installed at the sample inlet and outlet on the upper layer of the chip to facilitate automatic control. The liquid separation performance of the chip was verified by an automated platform. Finally, using the constructed KRAS gene mutation detection system, it is verified that the chip has good application potential for digital polymerase chain reaction (dPCR). The experimental results show that the chip has a stable performance and can achieve a dynamic detection range of four orders of magnitude and a gene mutation detection of 0.2%. In addition, the four-color fluorescence detection system developed based on the chip can distinguish three different KRAS gene mutation types simultaneously on a single chip.
Full article
(This article belongs to the Special Issue Biosensing for Point-of-Care Diagnostics)
►▼
Show Figures
Figure 1
Journal Menu
► ▼ Journal Menu-
- Biosensors Home
- Aims & Scope
- Editorial Board
- Reviewer Board
- Topical Advisory Panel
- Instructions for Authors
- Special Issues
- Topics
- Sections & Collections
- Article Processing Charge
- Indexing & Archiving
- Editor’s Choice Articles
- Most Cited & Viewed
- Journal Statistics
- Journal History
- Journal Awards
- Conferences
- Editorial Office
Journal Browser
► ▼ Journal BrowserHighly Accessed Articles
Latest Books
E-Mail Alert
News
Topics
Topic in
Applied Nano, Biosensors, Chemosensors, Materials, Sensors
Nanomaterial Based Gas Sensors for Environmental Air Pollutant Detection
Topic Editors: Tesfalem Welearegay, Radu IonescuDeadline: 30 September 2023
Topic in
Applied Sciences, Biosensors, J. Imaging, Sensors, Signals
Bio-Inspired Systems and Signal Processing
Topic Editors: Donald Y.C. Lie, Chung-Chih Hung, Jian XuDeadline: 30 November 2023
Topic in
Bioengineering, Healthcare, JCM, JSAN, Sensors, Applied Sciences, Biosensors
Machine Learning and Biomedical Sensors
Topic Editors: Massimo Martinelli, Davide Moroni, Aleš ProcházkaDeadline: 31 December 2023
Conferences
Special Issues
Special Issue in
Biosensors
SPR Biosensors and Their Applications
Guest Editor: Maria Laura ErminiDeadline: 20 August 2023
Special Issue in
Biosensors
Fluorescent Protein-Based Sensing and Detection
Guest Editors: Patrick Schaeffer, Alanna E. SorensonDeadline: 30 August 2023
Special Issue in
Biosensors
Plasmonic Based Biosensors
Guest Editors: Shuohui Cao, Yu Tao, Xiaoqing Liu, Lei ZhangDeadline: 20 September 2023
Special Issue in
Biosensors
Nano/Micro Biosensor for Biomedical Applications
Guest Editors: Jin-Ho Lee, Ki Su KimDeadline: 30 September 2023
Topical Collections
Topical Collection in
Biosensors
Recent Developments in Microfluidics
Collection Editors: Yunus Alapan, Yuncheng Man
Topical Collection in
Biosensors
Biosensors for Point-of-Care Diagnostics
Collection Editor: Guozhen Liu
Topical Collection in
Biosensors
Wearable Biosensors for Healthcare Applications
Collection Editors: Ming-Yih Lee, Wen-Yen Lin